| LREN12AY1B / LRNUN5AY1 | ||||
|---|---|---|---|---|
| Jäähdytysteho | Keskilämpötila | kW | kW | 31.7 (4) |
| Alhainen lämpötila | kW | kW | 17.3 (3) | |
| Ottoteho | Keskilämpötila | Nim. | kW | 20.1 (4) |
| Alhainen lämpötila | Nim. | kW | 18.6 (3) | |
| COP | Medium temperature | Nim. | 1.58 (4) | |
| Low temperature | Nim. | 0.93 (3) | ||
| Huomautukset | (1) - Minimum load of each individual refrigeration indoor unit: 3 KW (for Medium Temperature Operation) | |||
| (2) - Minimum load of each individual refrigeration indoor unit: 2 KW (for Low Temperature Operation). | ||||
| (3) - Nimellisolosuhteet: kylläinen lämpötila vastaa imupainetta: -35 °C (LT), ulkolämpötila 32 °C, imu SH 10K. | ||||
| (4) - Rated conditions: saturation temperature equivalent to suction pressure: -10°C (MT), outdoor temp. 32°C, Suction SH 10K | ||||
| (5) - Sound pressure data: measured at 1m in front of unit, at 1.5m height. Nominal operation condition – Medium evaporation temperature (MT) | ||||
| (6) - For MT (Medium Temperature) Operation | ||||
| (7) - For LT (Low Temperature) Operation | ||||